久久超碰97人人做人人爱_日韩一区精品视频一区二区_ ,欧美无人区码SUV,国产一区二区乐插,亚洲天堂在线观看视频,精品一区二区三区无码视频 ,又黄又爽又无遮挡在线观看免费_亚洲宅男精品一区在线观看_在线观看国产一级强片_怎么看黄片

Contact Us

Waterproof Cooling Fan Motor Protection

Date: 2015-2-27   Click: 1451 Times

From "Waterproof Cooling Fan" inside the motor is concerned, it has internal protection devices, there is a thermal circuit breaker is part of the coil windings shorted, resulting in a sharp increase in heat, open circuit breakers, motor under such circumstances, the general strike . This rarely happens. Another is to start capacitance becomes smaller, although the nameplate reads those parameters, but a long time, the capacitance is reduced, resulting in a starting torque "Waterproof Cooling Fan" motor is smaller, can not drive the load. This simple, remove the capacitors, go to a new one, the same model should be no problem. But the best for a 20% larger than the original, and will get better results. Motor shaft axial clearance is too large can cause can not drag the load. If you are disassembling the motor shaft axial gap is too large to be adjusted by adjusting the shims. When installing "Waterproof Cooling Fan" motor, the rotor and the bearing must be concentric job, slowly tightening the screws diagonally want, and then use a screwdriver to knock wood shaft, making concentric.

Back to: Industry news

+86-0769-83660708

Home Product News Contact